Dos and DON’Ts of Your AODD Pump


AODD pumps are usually regarded as trustworthy in critical applications owing to its simple design and maintenance issues.
This will aid the consumers in maintaining their AODD Pump and also ensuring quick, handy answers in times of demand.

Ø DO's of AODD pumps:

Check Air supply pressure.
Check suction piping to be certain that it is all connected and tight, all valves are available and ducting flooded suction, the finish of this pipe is below the liquid levels (take care not to use piping smaller than pump vent connections).
Do set up the Air Operated Double Diaphragm Pump as close to the source tank as possible.
Do depart the required working area around the pumping unit.
Do use large, brief, and directly suction piping.
Do Record pump model serial and no. And document for future reference.
Do obtain, read, and keep maintenance instructions furnished with your own pump.
Do inspect (ESADS) Air distribution valve if found pump is not cycling.
Do set up elastic straps along with a pulsation dampener at the other hand to decrease the pulsation in flow, keep the suction line length and amount of fitting to a minimum.
Do set up a pressure regulating valve to insist air supply pressure does not exceed recommended limits, please flush the pump after each use to keep the damage when it is used for liquid/ material that tends to settle out or out.
In freezing temperatures, the pump must be completely drained between the applications in all scenarios. You can also Know the entire process of how Peristaltic Pump works by Antlia Engineering Works.
When used for poisonous and aggressive fluids, then the pump must always be flushed clean before disassembly.
When managing flammable liquids, pumps, piping, valves, containers have to be grounded, airborne contaminants and sound hazardous, do wear eye and ear protection.

Ø DON'T's of all AODD pumps:

Don't run the pump at rates faster than shown in the catalog in accordance with the chosen model.
Don't require a pump to develop pressure higher than those shown in the catalog for your own model.
Do not run pumps at temperatures above and below limits displayed in the catalogue for your own pump.
Do not stick fingers from the ports of the pump! Serious injury may result. Do not reduce the suction line diameter.

Comments

  1. I got here much interesting stuff. The post is great! Thanks for sharing it! Self Priming Trash Pump

    ReplyDelete

Post a Comment

Popular posts from this blog

Air Operated Double Diaphragm (AODD) Pump Guide | Antliaworks

Air Operated Double Diaphragm (AODD) Pump Guide | Antliaworks Air Operated Double Diaphragm (AODD) pumps have a range of applications across various industries. Here, we shares the tips and tricks he’s picked up when it comes to maintaining AODD pumps. AODD pumps are the real workhorses of the industrial pump world and are used in a wide range of industries. These include chemicals, food processing, paints, electronics, road construction, maintenance for industrial processes, electricity production facilities, food processing, wastewater and sludge processing, and mining.They are self-priming, will run dry without doing any damage and use no electricity. Powered completely from compressed air, they are used in applications where electricity is not available or must not be used, such as hazardous or explosive situations or at remote sites. Checkout best aodd pump suppliers in India. The Basic Components of an AODD Pump AODD pumps are particularly versatile in being capable of pumping f...

OPTIMIZING USAGE OF AIR IN AODD PUMPS

In the industrial areas, there are some important operational costs – whether in the chemical processing, food & beverage, oil & gas, pharmaceutical, or mining industries – are the ones incurred for the purchase, operation & maintenance of pumps used during different production & transfer. One hidden component from the operating-cost perspective is the electricity used by double diaphragm pump , as per a study done by the Hydraulic Institute, account for nearly 20 percent of the world’s electricity demand. Assuming 7 cents per kilowatt/hour that equates to approximately $294 billion to operate diaphragm pump. Therefore, energy consumption can make up close to 90 percent of the total life-cycle costs of owning & operating a pump. Approximately 30 to 50 % of the energy consumed by pump systems can be saved by using air operated double diaphragm pump. Considering all the usage estimates, simple calculation reveals that up to $147 billion of electricity costs ...

Double Diaphragm Pump

What’s a double diaphragm pump? An air worked double diaphragm pump (also known as a Double-Membrane pump, pneumatic diaphragm pump or air-worked diaphragm pump) is a positive displacement pump that utilizes a mix of the responding activity of an elastic, thermoplastic or Teflon/pate diaphragm and appropriate valves on either side of the diaphragm (check valve, butterfly valves, fold valves, or some other type of stop valves) to pump a fluid. Diaphragm Pumps also known as Air Operated Double Diaphragm Pump ( AODD pump ), is a sort of responding positive displacement pump in which fluid is pumped by a responding diaphragm, which is driven by a solenoid, mechanical drive, or fluid drive. Different forms are air worked Pump has inlet & outlet check values. Diaphragm pump has great dry running qualities; they can be up to 97% effective. Diaphragm Pumps can deal with exceedingly thick fluids. A double diaphragm pump is known as a positive displacement pump. It utilizes t...