AODD pumps are usually regarded as trustworthy in critical applications owing to its simple design and maintenance issues.
This will aid the consumers in maintaining their AODD Pump and also ensuring quick, handy answers in times of demand.

Ø DO's of AODD pumps:

Check Air supply pressure.
Check suction piping to be certain that it is all connected and tight, all valves are available and ducting flooded suction, the finish of this pipe is below the liquid levels (take care not to use piping smaller than pump vent connections).
Do set up the Air Operated Double Diaphragm Pump as close to the source tank as possible.
Do depart the required working area around the pumping unit.
Do use large, brief, and directly suction piping.
Do Record pump model serial and no. And document for future reference.
Do obtain, read, and keep maintenance instructions furnished with your own pump.
Do inspect (ESADS) Air distribution valve if found pump is not cycling.
Do set up elastic straps along with a pulsation dampener at the other hand to decrease the pulsation in flow, keep the suction line length and amount of fitting to a minimum.
Do set up a pressure regulating valve to insist air supply pressure does not exceed recommended limits, please flush the pump after each use to keep the damage when it is used for liquid/ material that tends to settle out or out.
In freezing temperatures, the pump must be completely drained between the applications in all scenarios. You can also Know the entire process of how Peristaltic Pump works by Antlia Engineering Works.
When used for poisonous and aggressive fluids, then the pump must always be flushed clean before disassembly.
When managing flammable liquids, pumps, piping, valves, containers have to be grounded, airborne contaminants and sound hazardous, do wear eye and ear protection.

Ø DON'T's of all AODD pumps:

Don't run the pump at rates faster than shown in the catalog in accordance with the chosen model.
Don't require a pump to develop pressure higher than those shown in the catalog for your own model.
Do not run pumps at temperatures above and below limits displayed in the catalogue for your own pump.
Do not stick fingers from the ports of the pump! Serious injury may result. Do not reduce the suction line diameter.

Comments

  1. I got here much interesting stuff. The post is great! Thanks for sharing it! Self Priming Trash Pump

    ReplyDelete

Post a Comment

Popular posts from this blog

Air Operated Double Diaphragm (AODD) Pump Guide | Antliaworks

Air Operated Double Diaphragm (AODD) Pump Guide | Antliaworks Air Operated Double Diaphragm (AODD) pumps have a range of applications across various industries. Here, we shares the tips and tricks he’s picked up when it comes to maintaining AODD pumps. AODD pumps are the real workhorses of the industrial pump world and are used in a wide range of industries. These include chemicals, food processing, paints, electronics, road construction, maintenance for industrial processes, electricity production facilities, food processing, wastewater and sludge processing, and mining.They are self-priming, will run dry without doing any damage and use no electricity. Powered completely from compressed air, they are used in applications where electricity is not available or must not be used, such as hazardous or explosive situations or at remote sites. Checkout best aodd pump suppliers in India. The Basic Components of an AODD Pump AODD pumps are particularly versatile in being capable of pumping f...

Characteristics and best uses of Diaphragm Pump

A  diaphragm pump (also known as a Membrane pump) is a positive displacement pump that uses a combination of the reciprocating action of a rubber, thermoplastic or Teflon diaphragm and suitable valves on either side of the diaphragm (check valve, butterfly valves, flap valves, or any other form of shut-off valves) to pump a fluid.  Diaphragm pumps, also called double diaphragm pump , are utilized in a wide range of enterprises. At the point when the volume of an assembly of either sort of pump is expanded (the diaphragm climbing), the weight diminishes, and fluid is drawn into the chamber. At the point when the chamber weight later increments from diminished volume (the diaphragm moving down), the fluid recently attracted is constrained out. An elastomeric diaphragm can be utilized as a versatile dynamic seal that expels a large number of the impediments found with other fixing techniques. They don't release, offer littl...

HOW DOES AODD PUMP WORKS ?

AODD pumps are important, durable, protean, and able of handling nearly any process fluid, from water to thick, unpredictable, and indeed dangerous liquids when duly applied. Then's a introductory manual on AODD pumps and how they serve. An air-operated double-diaphragm pump is a positive relegation pump that utilizes compressed air by acting on a brace of repaying elastomeric diaphragms that alternatively “ pull and push” fluids or flowable maquillages through a stopcock system/ pumping chambers and out of the pump’s discharge. Also see : Best Aodd pump suppliers in india It transports fluid using two diaphragms, each separating the motive air from the fluid being pumped. Each diaphragm has its own pump chamber where it generates expanding and contracting depressions of fixed volume relegation. The rate is determined by the speed of the pump’s integral air stopcock medium delivering and exhausting air from the air chambers that fill and clear the depressions. Also read : Best A...